High-sensitivity ultrasonic partial discharge inspection instrument can capture weak ultrasonic signals



This is very important for the maintenance and fault diagnosis of power systems. Below is an overview of an article about the high-sensitivity ultrasonic partial discharge inspection instrument:



High-Sensitivity Ultrasonic Partial Discharge Inspection Instrument

Introduction

With the continuous expansion of the power system scale and the increasing emphasis on the reliability of power equipment, partial discharge detection technology has become a key link in power equipment maintenance. Partial discharge not only leads to a decline in the insulation performance of power equipment but may also cause serious safety accidents. Therefore, it is particularly important to develop a high-sensitivity partial discharge inspection instrument capable of capturing weak ultrasonic signals.



Product Overview

Name: High-Sensitivity Ultrasonic Partial Discharge Inspection Instrument

Model: [Specific Model]

Manufacturer: [Manufacturer Name]

Main Features

High Sensitivity: The inspection instrument adopts advanced ultrasonic sensors, capable of capturing weak ultrasonic signals, with sensitivity up to [Specific Value] dB or above.

Wide Frequency Band: Covers a wide range of ultrasonic frequencies, typically from 20kHz to 200kHz, or even higher.

Portable Design: Lightweight and easy to carry, suitable for on-site operations.

Multifunctional Display: Equipped with a high-definition color LCD screen, displaying detection results and setting parameters.

Built-in Storage: Can save a large amount of detection data for subsequent analysis.

Long Battery Life: Supports long-duration continuous operation.

Quick Positioning: Helps locate discharge sources through sound indication and numerical display.

Working Principle

Ultrasonic Detection: When partial discharge occurs, ultrasonic signals are generated, which can be captured by ultrasonic sensors.

Signal Amplification and Processing: The signals captured by the sensor are amplified and processed through digital signal processing to enhance the signal and remove interference.

Display and Analysis: The processed signals are converted into visual data and charts, displayed on the screen for convenient analysis by technicians.

Technical Parameters

Detection Frequency: 20kHz to 200kHz

Sensitivity: ≥100dB

Dynamic Range: ≥60dB

Battery Life: ≥8 hours

Display: High-definition color LCD, resolution [Specific Resolution]

Dimensions and Weight: [Specific Length]×[Specific Width]×[Specific Thickness], weight [Specific Weight]kg

Operating Temperature: -20℃ to +50℃

Storage Temperature: -40℃ to +70℃

Application Scenarios

Power Transformers: Detect partial discharge phenomena inside transformers.

Switchgear: Including high-voltage switchgear and ring main units.

Cable Joints: Inspect the insulation condition of cable joints and terminations.

GIS/GCB: Detect partial discharge in gas-insulated switchgear.

Motors: Evaluate the insulation status of motors.

Usage Instructions

Power On: Press the power button to start the device.

Settings: Adjust parameters such as detection frequency and sensitivity.

Detection: Place the probe close to the equipment under test and observe the screen display.

Positioning: Locate the discharge source based on sound prompts and numerical display.

Data Recording: Save detection data.

Power Off: After detection, press and hold the power button to turn off the device.

Maintenance and Care

Cleaning: Wipe the device surface with a soft cloth.

Storage: Store in a dry and ventilated place.

Calibration: Regularly calibrate the device.

Safety Precautions

Read Before Operation: Please read the user manual carefully.

Protective Measures: Wear necessary personal protective equipment.

No Touching: Do not touch high-voltage equipment.

Conclusion

The high-sensitivity ultrasonic partial discharge inspection instrument is an important tool in power system maintenance. It helps technicians detect potential partial discharge problems early, enabling preventive measures to ensure the safe and stable operation of the power system.