Desktop|中文
Home About Us Products + News Center Technical Articles Messages Contact Us

Product Details

全自动Dielectric Loss Tester-扬州达瑞

GYSB10KVA/100KV High Voltage Test Transformer - Yangzhou Darui

Published: 2020-08-27 08:31:23

Views: 2922

Category: Power Frequency Withstand Voltage Device

Product Description
GYSB10KVA/100KV High Voltage Test Transformer 

Darui Electric recommends for you:


Detailed Product Introduction







 



1. Working Principle of High Voltage Test Transformer:

   1.1 AC, AC/DC High Voltage Test Transformer:



   GYSB10KVA/100KV High Voltage Test Transformer inputs the power frequency power supply into the operation box (or operation console), and adjusts the voltage through the auto voltage regulator to input to the primary winding of the test transformer.According to the principle of electromagnetic induction, power frequency high voltage can be obtained in the secondary (high voltage) winding. This power frequency high voltage can be rectified by high-voltage silicon stack and filtered by capacitor to obtain DC high voltage, whose amplitude is 1.4 times the effective value of the power frequency high voltage. However, when using DC, the short-circuit rod should be pulled out; when using AC, insert the short-circuit rod.

   1.2 High Voltage Test Transformer with Taps:

   In order to simultaneously resolve the contradiction between high voltage and low current, and low voltage and high current, the high voltage winding is divided into two windings: one with larger current and the other with smaller current. Then the two windings are connected in series and led out separately. Schematic diagram of the principle.

   1.3 Cascade High Voltage Test Transformer:

   To obtain a higher voltage test transformer, the cascade method can also be used to achieve higher voltage. Figure 2 shows the principle wiring diagram of a three-stage cascade test transformer. The capacity and voltage relationship of the three transformers satisfies: P1=2P2=3P3, U(total)=1U+2U+3U.



GYSB10KVA/100KV High Voltage Test Transformer



2. Main Technical Indicators of High Voltage Test Transformer:



    >Rated Capacity: 1~300KVA

    >Rated Output Voltage per Unit:

    (AC) 50, 100, 150, 200, 300KV

    (DC) 70, 140, 210, 280KV

    >Rated Input Voltage: 200V, 400V

    >Transformation Ratio: 500/1, 1000/1, 1500/1, 2000/1, 3000/1

    >Transformation Ratio Error: ≤±1.5%

    >Impedance Voltage: <10%





Note: The above information and technical parameters are compiled and released by Yangzhou Darui Electric Co., Ltd.
WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us