HLY-200A Loop Resistance Tester
Product Introduction
Currently, the conventional QJ44 double-arm DC bridge is commonly used in power systems for measuring contact resistance. However, the test current of such bridges is only at the mA level, making it difficult to detect defects such as reduced cross-sectional area of loop conductors. When measuring the contact resistance of high-voltage switch conductive loops, the measured value can be several times larger due to the influence of oil films and oxide layers between contacts, failing to reflect the true contact resistance value. To address this, the Ministry of Electric Power standard SD301—88 "Procedures for Handover and Preventive Tests of AC 500KV Power Equipment" and the new edition of "Procedures for Preventive Tests of Power Equipment" stipulate that the measurement current for contact resistance of circuit breakers and disconnectors shall not be less than DC 100A, ensuring accurate test results.
HLY-200A Loop Resistance Tester is designed by combining high-frequency switching power supply technology with digital circuit technology. It is suitable for measuring the loop resistance of switch control equipment. The test current adopts DC 100A and 200A as recommended by national standards. The loop resistance can be measured directly at a current of 100A, or at 200A, with results displayed digitally. This instrument offers accurate measurement and stable performance, meeting the requirements for on-site high-voltage switch maintenance and loop resistance testing in power and supply departments.
Product Features
1. High Current: Utilizes the latest power supply technology to continuously output high current for extended periods, overcoming the drawbacks of instantaneous current from pulse power supplies, effectively breaking through the oxide film on switch contacts for reliable test results.
2. Strong Anti-interference Capability: Under severe interference conditions, the last digit of the LCD reading remains stable within ±1 digit, ensuring stable readings and good repeatability.
3. Long Service Life: All high-precision resistors are used to effectively eliminate the influence of ambient temperature on measurement results, and the use of military-grade connectors enhances vibration resistance.
4. Portability: Compact size and light weight.
![]()
Product Parameters
1. Measurement Range: 1~1999μΩ.
2. Resolution: 1μΩ.
3. Test Current: DC 50A, 100A, 150A, 200A four fixed output levels.
4. Measurement Accuracy: 0.5%±1d.
5. Working Mode: Continuous.
6. Display: Three and a half digit LCD.
7. Power Supply: AC220V±10% , 50Hz.
8. Operating Environment: Temperature -10℃~40℃ Humidity ≤80 %RH.
9. Dimensions: 380mm×350mm×260mm.
10. Weight: 9.6Kg (excluding accessories).
Product Accessories
|
Name |
Description |
Quantity |
|
Main Unit |
/ |
1 unit |
|
Special Test Leads |
Two 4m high-current leads, two high-current test clips, two 4m voltage test leads |
1 set |
|
Ground Wire |
/ |
1 piece |
|
Fuse |
10A |
3 pieces |
|
Accessory Bag |
/ |
1 piece |
|
Power Cord |
AC 220V |
1 piece |
|
User Manual |
/ |
1 copy |
|
Inspection Report |
/ |
1 copy |
|
Certificate of Conformity |
/ |
1 piece |