Desktop|中文
Home About Us Products + News Center Technical Articles Messages Contact Us

Product Details

全自动Dielectric Loss Tester-扬州达瑞

10KVA/400V Induced Overvoltage Withstand Test Device

Published: 2020-08-26 09:10:17

Views: 2922

Category: Induction Withstand Voltage Test Device

Product Description

10KVA/400V Induced Overvoltage Withstand Test Device

Dare Electric recommends for you:

Product Overview:



 10KVA/400V Induced Overvoltage Withstand Test Device manufacturer price, for power transformers, voltage transformers and other test objects, in addition to performing external power frequency high voltage tests on the main insulation of fully insulated transformers, it is also necessary to conduct induced high voltage tests on the longitudinal insulation of transformers and the main insulation of semi-insulated transformers.



10KVA/400V Induced Overvoltage Withstand Test Device manufacturer price, according to national test standards, the induced test voltage for power transformers and voltage transformers is approximately 2 to 3 times the maximum working phase voltage. As is well known, when a transformer operates at rated frequency and rated voltage, the iron core is close to saturation. If a power frequency power source is used to apply a test voltage greater than the rated voltage across the windings of the transformer under test, the no-load excitation current will increase sharply to an unacceptable level. From the relationship of induced electromotive force, it can be seen that in order to apply a test voltage greater than the rated voltage without saturating the iron core, the method of increasing the power frequency (f) can be adopted, and a power source with a frequency greater than the multiple of the power frequency must be used.



Operating Environment:



1. Power supply conditions: Three-phase 380V/50Hz



2. Ambient temperature: -15℃ to 40℃



3. Altitude: not exceeding 1000 meters



Technical Data:

































































































Model Specification



Rated Capacity (KVA)



Input Voltage (V)



Input Current (A)



Output Voltage (V)



Output Current (A)



Output Frequency (Hz)



Weight (kg)



5KVA/300V



5



400



7.6



300



16.7



150



28



5KVA/500V



5



400



7.6



500



10



150



28



10KVA/300V



10



400



15.2



300



33.3



150



55



10KVA/400V



10



400



15.2



400



25



150



55



15KVA/600V



15



400



22.8



600



25



150



75



20KVA/500V



20



400



30.4



500



40



150



85



30KVA/500V



30



400



45.6



500



60



150



95



50KVA/500V



50



400



76



500



100



150



135









Note: The above information and technical parameters are compiled and released by Yangzhou Dare Electric Co., Ltd.
WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us